              1. IK & IP Testing for Lighting Products

                2025-08-01

                IK & IP Testing for Lighting Products

                Ratings that demonstrate the degree of Impact Protection (IK) and Ingress Protection (IP) are critical for street, roadway and other lighting products. IP ratings are required per IEC/EN 60598-2-3 for all roadway and street applications. IK ratings are required in specific applications when high impact glass provides protection for the enclosed lamp.

                Standards

                IEC 62262 specifies the way enclosures should be tested for IK ratings which are defined as the level of protection the enclosures provided against external mechanical impacts. IEC 60598-1 (IEC 60529) specifies the test method used to classify and rate the degree of protection an enclosure provides against intrusion of various sized solid objects from fingers and hands to fine dust and the protection against water intrusion from falling drops to a high pressure water jet. IEC 60598-2-3 is the International Standard for Luminaires for Road and Street Lighting.

                UL offers complete testing and certification services for street and roadway luminaires to IEC 60598-2-3

                IK ratings are defined as IKXX, where “XX” is a number from 00 to 10 indicating the degrees of protection provided by electrical enclosures (including luminaires) against external mechanical impacts. The IK rating scale identifies the ability of an enclosure to resist impact energy levels measured in joules (J). IEC 62262 specifies how the enclosure must be mounted for testing, the atmospheric conditions required, the quantity and distribution of the test impacts and the impact hammer to be used for each level of IK rating.

                Degrees if protection again external mechanical impacts

                IK00

                IK01

                IK02

                IK03

                IK04

                IK05

                IK06

                IK07

                IK08

                IK09

                IK10

                Non-protected

                0.14J

                0.2J

                0.35J

                0.5J

                0.7J

                1J

                2J

                5J

                10J

                20J

                1.jpg


                IP ratings are defined as IPXX where the first X indicates the degree of protection against solid objects and the second X indicates the degrees of protection against water. A luminaire or lighting component with a rating of IP66 is dust-tight and protected against powerful water jets as described in IEC 60598-1 (IEC 60529).]

                Degrees if protection again solid objects

                IP0X

                Non-protected

                IP1X

                50mm diameter and greater

                IP2X

                12.55mm diameter and greater

                IP3X

                2.5mm diameter and greater

                IP4X

                1.0mm diameter and greater

                IP5X

                Dust-protected

                IP6X

                Dust-tight

                2.jpg


                Degrees if protection again water

                IP0X

                Non-protected

                IP1X

                Vertically falling water drops

                IP2X

                Vertically falling water drops with enclosure tilted

                IP3X

                Spraying water

                IP4X

                Splashing water

                IP5X

                Water jets

                IP6X

                Powerful water jets

                IP7X

                Temporary immersion

                IP8X

                Continuous immersion