              1. ORP10 ORP Transmitter Oxidation Reduction Potential Sensor

                Oxidation Reduction Potential (ORP) is a measurement of sanitizer effectiveness in water. ORP is an electronic measurement in millivolts (mV) of the ability of a chemical substance to oxidize or reduce another chemical substance. The output signal can be RS485, Analog Voltage or Analog Current. The sensor is applicable for industrial, water processing, sewerage system, irrigation, smart agriculture etc.
                Description

                Product Description:

                Name:ORP10 ORP Transmitter Oxidation Reduction Potential Sensor

                Type:ORP10

                Oxidation Reduction Potential (ORP) is a measurement of sanitizer effectiveness in water. ORP is an electronic measurement in millivolts (mV) of the ability of a chemical substance to oxidize or reduce another chemical substance. The output signal can be RS485, Analog Voltage or Analog Current. The sensor is applicable for industrial, water processing, sewerage system, irrigation, smart agriculture etc.

                ■ ORP measurement

                ■ Output Interface with RS485, Voltage, Current

                ■ High accuracy with excellent stability

                ■ Reverse power protection and Built-in TVS/ESD protection


                Specifications


                Output Interface

                Analog Voltage 0-2V        

                (Output resistance ~0ohm)

                Analog Current 4-20mA        

                (Load Resistor<500ohm)

                RS485        

                Modbus-RTU

                Power Supply

                3.9-30V/DC

                12-30V/DC

                3.9-30V/DC

                Power Consumption

                10mA@24V DC

                30mA@24V DC        

                (with 20mA output signal)

                10mA@24V DC

                ORP Measurement

                Range:+/-2000mV,Resolution:1mV,Accuracy:±2%

                IP Ratings

                Electrode:IP68        

                Transmitter:IP65

                Operating Temperature

                -40~85℃

                Installation

                Electrode:3/4″NPT screw threads        

                Transmitter:Mounting hole

                Cable Length

                Power and Signal Cable:2 meters or Customize        

                Electrode Cable:5 meters

                Dimension

                Electrode:3/4″NPT screw threads        

                Transmitter:128*70*42mm



                Parameters

                Code

                Comments

                Code 1:        

                Product Series

                ORP10

                ORP10 transmitter

                Code 2:        

                Power Supply

                A        

                B

                3.9-30V DC        

                3.3-16V

                Code 3:        

                ORP Range

                A        

                B

                C

                +/-2000mV        

                +/-1000mV

                Customize

                Code 4:        

                Output Interface

                A        

                B

                C

                D

                E

                F

                G

                Analog Voltage 0-2V        

                Analog Current 4-20mA

                RS485,Modbus-RTU

                RS485,Modbus-RTU & Analog Voltage 0-2V

                RS485,Modbus-RTU & Analog Current 4-20mA

                SDI-12

                Customize

                Code 5:        

                Cable Length

                002        

                XXX

                Electrode Cable:5 meters , Power and Signal Cable:2 meters        

                Electrode Cable:5 meters , Power and Signal Cable:xxx meters

                Ordering Code Example:

                ORP10 transmitter Power Supply 3.9-30V DC, ORP Range +/-2000mV, Output Interface RS485, Modbus-RTU, Power and Signal Cable Length 5 meters. Ordering Code is : ORP10 – A A C 005