1. <fieldset></fieldset>

          1. <em id="Svkcvd"></em><ins id="Svkcvd"><dir></dir></ins>
              1. UL 94 Horizontal and vertical flame test apparatus BND-SPR

                The horizontal and vertical burning test mainly refers to UL 94-2006, IEC 60695-11-4, IEC 60695-11-3, GB/T5169-2008 series and other standards, using Bunsen burner of specified size and specific gas source (Methane or propane), according to a certain flame height and a certain flame angle, the test sample in a horizontal or vertical state is regularly burned several times, and its flammability is evaluated by the duration and burning length of the test sample‘s ignition and burning. Sex and fire hazard.
                Description

                Product Description:

                Name:UL 94 Horizontal and vertical flame test apparatus

                Type:BND-SPR


                The Basic introduction of the flame tester:

                1. The horizontal and vertical burning test mainly refers to UL 94-2006, IEC 60695-11-4, IEC 60695-11-3, GB/T5169-2008 series and other standards, using Bunsen burner of specified size and specific gas source (Methane or propane), according to a certain flame height and a certain flame angle, the test sample in a horizontal or vertical state is regularly burned several times, and its flammability is evaluated by the duration and burning length of the test sample's ignition and burning. Sex and fire hazard.

                2. HVR-4 horizontal and vertical combustion tester is mainly used for grading assessment of the flammability of V-0, V-1, V-2, HB, and 5V materials. It is suitable for the research, production and quality inspection departments of electrical and electronic products and their components such as lighting equipment, low-voltage electrical appliances, household appliances, machine tool electrical appliances, motors, power tools, electronic instruments, electrical meters, electrical connectors and accessories. Used in insulation materials, engineering plastics or other solid combustible materials industries.


                Technical Parameter of flame test:

                Model

                BND-SPR   Horizontal vertical flame tester

                Kinds

                 500W(5V class )

                 50W(HB/V class)

                Test Flame

                500W(burning test for V-0,V-1,V-2  classification)

                50W(burning test for V-0,V-1,V-2 classification)

                Burner Tube

                Internal diameter: Φ 9.5mm±0.3mm

                Internal diameter: Φ 9.5mm±0.3mm, 

                Burning Angle

                0°,20°,45°

                0°,20°,45°

                Thermocouple

                Type K (Ni/Cr - Ni/Al)

                Type K (Ni/Cr - Ni/Al)

                Thermocouple Size 

                0.5 mm

                0.5 mm

                Standard Copper Block 

                9mm±0.01mm,

                weight:10g±0.05g before drilling.  

                5.5mm±0.01mm,

                weight:76g±0.01g before drilling.

                Time for Temperature to Increase

                From 100°C±5°C to 700°C±3°C; 54s±2s (preset)

                From 100°C±5°C to 700°C±3°C;

                44s±2s (preset)

                Gas Flow

                965±32ml/min

                105±10ml/min

                Gas Supply

                methane,min.98% purity

                methane,min.98% purity

                water-column 

                125m±5mm

                ‹10mm

                Test  Time

                54±2s

                44±2s

                Flame Height Indicator

                40±1mm

                20±1mm

                Volume Of Chamber

                >0.5m³, black interior

                >0.5m³, black interior

                Conform to standard

                UL94,IEC60695-11-3,IEC60695-11-20

                UL94,IEC60695-11-4,IEC60695-11-10

                yPaos