1. <fieldset></fieldset>

          1. <em id="Svkcvd"></em><ins id="Svkcvd"><dir></dir></ins>
              1. Integrated low pressure test chamber BND-HZHD

                It is mainly for the testing of the environment adaptability and reliability of the instruments and meters,electronic instruments ,materials and components in low-pressure,high-temperature and low-temperature under the condition of single or multiterm, and for the testing of electric parameters in the meantime.
                Description

                Product Description:

                Name:Integrated low pressure test chamber

                Type:BND-HZHD


                Purpose:

                It is mainly for the testing of the environment adaptability and reliability of the instruments and meters,electronic instruments ,materials and components in low-pressure,high-temperature and low-temperature under the condition of single or multiterm, and for the testing of electric parameters in the meantime.


                Standard Configuration:

                A copy of the instruction and test report for the product, A certificate and quality assurance.2 Shelf and 4 shelves .

                Remark:1,The hanging touch screen(240mm) has not including in the width of exterior dimension;2,water-cooled(water temperature 10-28℃,hydraulic pressure 0.1-0.3MPa,to ensure the cooling performance);3, The function of fast step-down for Optional.;4,The function of heating and humidification for optional.


                Product Spec.and Technical parameter table

                model

                BND-HZHD-500

                BND-HZHD-1000

                performance

                temperature range

                ﹣70~﹢150ºC

                temperature fluctuation

                ±0.5ºC(normal pressures,empty)

                temperature uniformity

                ≤2ºC(normal pressures,empty)

                temperature deviation

                ≤±3ºC(normal pressures,empty)

                heting time

                60min

                cooling time

                90min

                pressure range

                normal pressures~0.5kPa

                pressure deviation

                normal pressures~40kPa:±2kPa;40kPa~4kPa;±5%;4kPa~1kPa;±0.1kPa(≈1mmHg)

                decompression time

                ≤45min(normal pressures~0.5kPa)

                construction

                shell

                cooling steel plate,surface spray

                inner

                steel plate

                insulate

                Rigid Polyurethane Foam+extra-fine glass-wool

                Cooling System

                mode

                cascade refrigerating compressor

                compressor

                import compressor

                inspection window(mm)

                Φ250

                amphenol connector

                design by customer

                temperature sensor

                Pt-resistance Pt100

                pressure sensor

                pressure transmitter

                Controller

                PLC color LCD touch screen of Panasonic

                recording equipment

                temperature recorder(optional)

                communication Interface

                RS485 interface,RS232 interface

                Inner dimension(mm)

                D

                700

                1000

                W

                800

                1000

                H

                900

                1000

                Exterior dimension(mm)

                D

                2750

                3250

                W

                1500

                1400

                H

                1750

                2000

                Electromotor cover height(mm)

                235

                Total Power(kw)

                20

                38

                Power Supply

                AC380V 50Hz Three-phase four-wire + protective earth wire